Important! The maximum capacities listed for the Strata CIX40, CIX100, CIX200 and CIX670 in Tables 10~14 are based on an expanded system (Base + Expansion Cabinets).
Strata CIX40 capacities require CHSU40A2 and Release 5.1 software.
Table 10 Cabinet and Slot Capacities
Cabinets/Slots/Ports
|
CIX40
GCTU2A
|
CIX100
ACTU
|
CIX200
LCTU
|
CIX670
Basic
Processor
BCTU
|
CIX670
Expanded
Processor
BCTU + BEXU
|
Cabinets
|
1
|
1 to 2
|
1 to 2
|
1 to 2
|
1 to 7
|
Universal slots
|
Dedicated
slots
|
4 or 8
|
3 or 7
|
8 or 18
|
8 to 68
|
Maximum capacity of ports including Voice Mail ports (lines + stations)
|
57
|
112
|
192
|
192
|
672
|
Table 11 Station/Peripherals System Capacities
Stations
|
CIX40
|
CIX100
Base &
Expansion
|
CIX200
Base and
Expansion
|
CIX670
Basic
Processor
BCTU
|
CIX670
Expanded
Processor
BCTU + BEXU
|
Digital Add-on modules per Base Cabinet1
|
16 System
1 or 2 per DP
|
30 DPs with
1 DADM
23 DPs with
2 DADMs
|
46 DPs with 1
DADM
36 DPs with 2
DADMs
|
55 DPs with
1 DADM
43 DPs with
2 DADMs
|
55 DPs with 1
DADM
43 DPs with 2
DADMs
|
Digital Add-on modules
per Expansion Cabinet1
|
N/A2
|
31 DPs with
1 DADM
24 DPs with
2 DADMs
|
46 DPs with 1
DADM
36 DPs with 2
DADMs
|
57 DPs with
1 DADM
45 DPs with
2 DADMs
|
57 DPs with 1
DADM
45 DPs with 2
DADMs
|
CIX Attendant consoles
|
2
|
2
|
2
|
2
|
4
|
Table 11 Station/Peripherals System Capacities (continued)
Stations
|
CIX40
|
CIX100
Base &
Expansion
|
CIX200
Base and
Expansion
|
CIX670
Basic
Processor
BCTU
|
CIX670
Expanded
Processor
BCTU + BEXU
|
DP5000, DKT3200, 3000 and 2000-series DKTs1
|
16
|
72
(40 Base
Cabinet)
(40/Expan.
Cab.)
|
112
|
152
(72 Base
Cabinet)
(80/Expan.
Cab.)
|
552
(72 Base
Cabinet)
(80/Expan.
Cab.)
|
IP5000-series/IPT2000- series telephones3
|
24
|
64 per cabinet 72 per system
|
160 per System
80 per cabinet
|
80 Base
80
Expansion
160 System
|
80 Base
80 Expansion
560 System
|
KM5020, LM5110 and IADM2020 on IPTs4
|
48 per
system
2 IADM2020
per IPT
|
53 per cabinet 53 per system
|
58 per System
58 per cabinet
|
80 per cabinet 116 per system
|
80 per cabinet 400 per system
|
DKT2204-CT or DKT2304-CT Cordless Telephone1
|
16
|
72
|
112
|
152
|
552
|
Door locks5
|
3
|
4
|
5
|
5
|
10
|
Door phone control boxes (DDCB)
|
2
|
2
|
3
|
3
|
8
|
Door phones
|
6
|
6
|
9
|
9
|
24
|
DSS consoles (DSS)
|
3 per system
3 per station
|
3 per
system
3 per station
|
5 per system
5 per station
|
5 per system
5 per station
|
16 per system
8 per station
|
Off-premise stations
|
26
|
56
|
58
|
144
|
544
|
BPCI used for TAPI only: per cabinet1
|
167
|
35
|
48 Base Cabinet
54 Expansion
Cabinet
|
66
|
66
|
Total Stations (Digital/ Analog)
|
18
|
72
|
160
|
160
|
560
|
Standard stations8
|
2
|
56
|
58
|
144
|
544
|
Calls existing at the same time
|
unlimited
|
unlimited
|
96
|
96
|
366
|
| 1. | Limit is based on cabinet Power Factor (PF). |
| 2. | N/A means Not Available. |
| 3. | Limited by system bus traffic. |
| 4. | Limited by the number of flexible buttons per system. |
| 5. | Each Door lock reduces the number of Door Phones by one Door Phone and vice versa. |
| 7. | CIX40 cannot use 2B channels on digital telephones. |
| 8. | Capacity includes standard telephones with or without Caller ID interface. Caller ID interface requires R4.1 or later software. |
Table 12 Line Capacities and Universal Circuit Card Slots
Lines
|
CIX40
|
CIX1 00
Base &
Expansion
|
CIX200
Base and
Expansion
|
CIX670
Basic
Processor
BCTU
|
CIX670 Expanded Processor BCTU +
BEXU
|
CO lines – loop start (analog - 8 lines/slot)
|
11 with built-
in CLID
|
64
|
56
|
96
|
264
|
CO lines – ground start (analog - 4 lines/slot)
|
N/A1
|
32
|
28
|
72
|
264
|
DID lines (analog - 4 lines/slot)
|
N/A1
|
32
|
28
|
72
|
264
|
Tie lines (analog - 4 lines/slot)
|
N/A1
|
32
|
28
|
72
|
264
|
T1 lines (DS-1)2
|
N/A1
|
64
|
96
|
96
|
264
|
ISDN PRI B channel lines3
|
N/A1
|
48
|
96
|
96
|
264
|
Strata Net IP Channels4
|
24
|
48
|
96
|
96
|
264
|
SIP Trunking
|
24
|
48
|
96
|
96
|
264
|
Total lines (Analog, T1, and ISDN PRI B channels combined)
|
11
|
64
|
96
|
96
|
264
|
Channel Groups
|
1 (IP)
|
32
|
48
|
48
|
128
|
Number of groups w/ GCO Line buttons
|
8
|
32
|
50
|
50
|
128
|
| 1. | N/A means Not Available. |
| 2. | T1 lines can be loop start, ground start, Tie or DID (maximum 24 lines per unit, any type or combination). |
| 3. | PRI lines provide CO line services, including Strata Net Networking, Calling Party Number/Name, DID, Tie, POTS, FX and DIT. |
| 4. | IP Strata Net channels provides CIX networking functionality. |
Table 13 Digital and IP Telephone Station Buttons
Station Buttons per System
|
CIX40
|
CIX1 00 Base
& Expansion
|
CIX200
Base and
Expansion
|
CIX670
Basic
Processor
BCTU
|
CIX670
Expanded
Processor
BCTU + BEXU
|
Call Forward, Personal CF Buttons
|
24
|
72
|
160
|
160
|
560
|
Caller ID (CLID) button (DP or IPT only)
|
24
|
72
|
160
|
160
|
560
|
CO Line Buttons1
|
6
|
64
|
56
|
96
|
264
|
Group CO Line Buttons2
|
N/A
|
64
|
96
|
96
|
264
|
Pooled CO Line Buttons2
|
32
|
32
|
50
|
50
|
128
|
CO Group and Pooled Line Buttons2
|
N/A, 32
|
64
|
96
|
96
|
264
|
Door Unlock Buttons
|
24
|
32
|
64
|
64
|
64
|
Flexible Telephone Buttons
|
3200
|
3200
|
7000
|
7000
|
24000
|
Line and DN Buttons in use at the same time
|
96
|
1440
|
3360
|
3360
|
3360
|
Message Waiting Registration (DNs with MW)
|
130
|
130
|
230
|
230
|
800
|
Multiple Appearances of DNs on Telephones
|
2300
|
2300
|
4200
|
4200
|
15000
|
Night Transfer Buttons
|
24
|
32
|
64
|
64
|
128
|
One Touch Buttons
|
1600
|
1600
|
3500
|
3500
|
12000
|
Primary Directory Numbers [PDNs] per system
|
30
|
72
|
160
|
160
|
560
|
Phantom Directory Numbers [PhDNs] per system
|
288
|
288
|
640
|
640
|
2240
|
[PhDNs] with Message Waiting Indication LED
|
18
|
18
|
38
|
38
|
128
|
| 1. | This is the number of unique CO Line Buttons (i.e., Line 1, Line 2, etc.). The total number of CO Line Buttons can not exceed the Flexible Telephone Button limit. Example: If Line 1 button appears on 10 telephones, it counts as one button. |
| 2. | This is the total number of all GCO or Pooled Line Buttons allowed in a system. Example: If the GCO1 button appears on 10 telephones, it counts as 10 buttons. |
Table 14 System Feature Capacities
Features
|
CIX40
|
CIX1 00
Base &
Expansion
|
CIX200
Base and
Expansion
|
CIX670
Basic
Processor
BCTU
|
CIX670 Expanded Processor BCTU +
BEXU
|
Pilot DNs
|
90
|
90
|
200
|
100
|
256
|
Advisory LCD Messages (Set on a Telephone)
|
1
|
1
|
1
|
1
|
1
|
Advisory LCD Messages Lists (per System)
|
10
|
10
|
10
|
10
|
10
|
Attendant Groups
|
1
|
1
|
1
|
1
|
1
|
Call Accounting SMDR Interface1
|
1
|
1
|
1
|
1
|
1
|
Call Forward, System CF Patterns
|
4
|
4
|
10
|
10
|
32
|
Call Park Orbits (General)
|
14
|
14
|
32
|
32
|
64
|
Call Park Orbits (Individual)
|
56
|
56
|
96
|
96
|
336
|
Minimum / Maximum Caller ID per Station
|
Minimum: 10; Maximum: 100
|
Maximum number of Stations that can have Caller ID/ANI/CNIS Numbers stored (Call History records)
|
66
|
66
|
100
|
100
|
200
|
Up to 660/
system
|
Up to 660/
system
|
Up to 1000/
system
|
Up to 1000/
system
|
Up to 2000/
system
|
Table 14 System Feature Capacities (continued)
Features
|
CIX40
|
CIX1 00
Base &
Expansion
|
CIX200
Base and
Expansion
|
CIX670
Basic
Processor
BCTU
|
CIX670 Expanded Processor BCTU +
BEXU
|
CO Line Groups - Incoming Line Groups (ILG)
|
11
|
32
|
50
|
50
|
128
|
CO Line Groups - Outgoing Line Groups (OLG)
|
11
|
32
|
50
|
50
|
128
|
Outgoing Line Groups (OLG) Members per
system (Trunks + ISDN Line Service Index)
|
96 (No
ISDN)
|
96
|
144
|
144
|
392
|
Conference Circuits
|
64
|
64
|
64
|
64
|
96
|
Conferencing (three-parties simultaneously)2
|
20
|
20
|
20
|
20
|
30
|
Conferencing (eight-parties simultaneously)2
|
8
|
8
|
8
|
8
|
12
|
Conference Party types (up to 8 total lines + stations)2
|
6 lines max.
8 stations
max.
|
6 lines
max.
8 stations
max.
|
6 lines
max.
8 stations
max.
|
6 lines max.
8 stations
max.
|
6 lines max.
8 stations
max.
|
Two-CO Line simultaneous Connection2 (Two party only, no telephone or VM port)
|
5
|
32
|
48
|
48
|
132
|
Conference/Line Volume Adjustment (PAD) Groups
|
6
|
6
|
10
|
10
|
32
|
DID Numbers for Calling Number ID/system
|
N/A3
|
225
|
500
|
500
|
1000
|
DNIS/DID Network Routing Numbers (8~32 digits)
|
N/A3
|
200
|
400
|
400
|
1000
|
DNIS/DID Numbers (total 4~7 digits)
|
N/A3
|
450
|
1000
|
1000
|
2000
|
DNIS/DID Numbers (4~7 and 8~32 digits)
|
N/A
|
450
|
1000
|
1000
|
2000
|
Network DNs
|
3000
|
3000
|
3000
|
3000
|
3000
|
DTMF Receivers4
|
16
|
16
|
16
|
16
|
32
|
E911 Groups
|
8
|
8
|
8
|
8
|
8
|
Emergency Call Groups
|
8
|
8
|
8
|
8
|
8
|
Hunt Groups (Serial/Circular/Distributed combined)
|
16
|
90
|
200
|
200
|
640
|
Hunt Group Size (DNs per group)
|
18
|
72
|
160
|
160
|
560
|
Hunt Group Stations (per system)
|
18
|
360
|
800
|
800
|
2800
|
ISDN Line Service Indexes
|
N/A
|
32
|
48
|
48
|
128
|
Multiple Call Ring Group
|
16
|
16
|
32
|
32
|
64
|
Night Bell Control Relay per tenant5
|
1
|
1
|
1
|
1
|
1
|
Night Transfer Control Relay per tenant5
|
1
|
1
|
1
|
1
|
1
|
Off-hook Call Announce Handsets (simultaneous)
|
20
|
20
|
20
|
20
|
30
|
Off-hook Call Announce to Telephone Speakers6
|
23 IPT shared 12 IPT dedicated
|
72
|
112
|
112
|
352
|
Page Mute External BGM Control Relay5
|
1
|
1
|
1
|
1
|
1
|
Page Zone Relays5
|
N/A
|
4
|
8
|
8
|
8
|
Table 14 System Feature Capacities (continued)
Features
|
CIX40
|
CIX1 00
Base &
Expansion
|
CIX200
Base and
Expansion
|
CIX670
Basic
Processor
BCTU
|
CIX670 Expanded Processor BCTU +
BEXU
|
Page Groups (Phones with or without External Zones)
|
4
|
4
|
8
|
8
|
8
|
Paging – (Group Page – simultaneous stations paged)
|
24
|
72
|
120
|
120
|
120
|
Pickup Groups
|
5
|
5
|
10
|
10
|
32
|
Ring Tones (External Call Ring Tones for DPs and IPTs)
|
10
|
10
|
10
|
10
|
10
|
Ring Tones (Internal Call Ring Tones for DPs and IPTs)
|
10
|
10
|
10
|
10
|
10
|
Speed Dial - Station SD numbers per system7
|
1080
|
1080
|
2400
|
2400
|
5600
|
Speed Dial - System SD numbers per system
|
800
|
800
|
800
|
800
|
800
|
Stratagy ES / iES 32 / GVPH / LVMU / IVP8 systems per system8
|
1
|
1
|
1
|
1
|
1
|
Tenants
|
8
|
8
|
8
|
8
|
8
|
Destination Restriction Level (DRL) Classes
|
16
|
16
|
16
|
16
|
16
|
Verified Account Codes
|
135
|
135
|
300
|
300
|
1000
|
Voice Mail SMDI Interface1
|
1
|
1
|
1
|
1
|
1
|
| 3. | SMDI and SMDR may require BSIS serial port or LAN interface. |
| 4. | Conference circuits are used dynamically, so the maximum number of simultaneous conferences is affected by the number of conference members in each conference. The total number of members in simultaneous conferences cannot exceed the total number of conference circuits. Each conference can have up to eight members. Two CO line connections do not require a conference circuit. |
| 5. | N/A means Not Available |
| 6. | DTMF receivers are required for standard touch tone telephones, voice mail integration, Tie, DID and DISA lines. |
| 7. | An option BIOU is required for up to four zone page relays and four control relays on the CIX100, CIX200 and CIX670 processor. One control relay and one 600 ohm page output is provided on board the CIXCIX100 and CIX200 processor but not the CIX670 processor. |
| 8. | On Digital telephones Speaker OCA capacity is determined by 2B channel slot availability and power supply. CIX40 supports Speaker OCA (S-OCA) on IP5000-series and IPT2000-series telephones only and not on digital telephones. S-OCA requires the DOCA-1A option in DP5000-series digital telephones, but not in IP telephones. Speaker OCA on IP telephones require an MIPU, LIPU or GIPU, GIPH installed in the Strata CIX. Each IP telephone with Speaker OCA requires two IP channels on the MIPU / LIPU or GIPU / GIPH but only requires one IP endpoint license. The IP OCA channel is only used while the S-OCA call is in progress so it can be reserved or shared with other telephones for S-OCA but cannot be used as a dedicated IP channel for another telephone or Strata Net channel. DP5008, IPT201 0-SD and IPT1 020-SD do not support Speaker OCA; all other current Toshiba telephones support S-OCA. |
| 9. | Up to 100 Station SD numbers, allocated in increments of 10, can be programmed per station. |
| 10. | CIX40 supports only the GVPH voice mail systems internally, and the Stratagy ES externally. |
|